Tender
Renal Dialysis Expansion
Overview
Albury Wodonga Health is seeking a construction company for their renal expansion project ALBURY BASE HOSPITAL: Recommissioning of two (2) existing renal care points within Medical Ward 2 (Room 6) WODONGA RENAL DIALYSIS SERVICE: Expansion of both the Satellite Renal Dialysis service, from nine (9) to fifteen (15) care points and; Home Dialysis Service from one (1) to three (3) care points.
Key Information
Provider
Victorian Government
GovernmentAgency
Albury Wodonga Health
Location
Wodonga, NSW, Australia
Reference Number
35514
Country
Details
Eligibility Criteria
- LocationWork is to be performed at Albury Wodonga Health, Wodonga Hospital, NSW, Australia.
- Scope of WorkContractors must be capable of performing mechanical services including installation of ductwork, pipework, insulation, and associated mechanical components as per the provided mechanical drawings and specifications.
Deliverables
- Installation of dual skin 100mm internally lined ductwork R3 or equal
- Installation of 75mm externally lined ductwork with sisalation or equal
- Installation of 50mm internally lined ductwork with 450 perforated sisalation RL2 or equal
- Installation of uninsulated and spiral ductwork as specified
- Installation of flexible ductwork and spigots with butterfly dampers
- Provision of access panels suitable for equipment servicing and damper adjustment
- Provision of seismic restraints and supports as per AS4254 Appendix C
- Painting internal surfaces of register boxes and return air boxes/ducts with matt black
- Installation of pipework including chilled water, heating hot water, condensate drainage, and drain waste as per schematic legend
- Installation of valves including globe, butterfly, stop, check, pressure relief, motorized, and balancing valves as specified
- Provision of vibration eliminators and flexible connections
- Coordination with architectural and other services documents
Conditions & Exclusions
- •All duct sizes noted are internal air first size noted denotes side of duct view
- •Confirm all dimensions on site prior to installation
- •All services to be concealed unless otherwise stated
- •Any discrepancy or omissions between drawings and specifications to be addressed to BSG for clarification prior to close of tender
Supporting Documents
Chat with Documents
AI PreviewAsk questions about this opportunity
Sign in to chat with grant documents and get instant answers
Similar Opportunities
Track This Opportunity
Sign up to get deadline reminders, save opportunities, and manage your applications in one place.
Start Free TrialSign InSmart Matching
Get personalized recommendations
Deadline Alerts
Never miss a submission date
AI Grant Brief
Profile Match
Bid Plan
AI-generated proposal writing guide with win themes, timeline and risk register.
Sign In to Generate PlanSuccess Analysis
Predict your likelihood of winning with an AI-powered success score and recommendations.
Sign In to View Score