Porepunkah - Nicholson Street - SPS - Remediation
Overview
North East Water previously engaged Remedy Asset Protection in 2025 to complete a condition assessment and recommendation for remediation for the Porepunkah (Nicholson St) SPS. The key outcome of the study was a recommendation that concrete degradation in the wet well be remediated. This project requires: • 100% detailed design of the concrete remediation including anchorages • Removal of other infrastructure and fittings from the wet well • Concrete remediation to provide 30-year minimum design life • Reinstatement of infrastructure including fittings and anchorages into the wet well The project excludes: • Remediation of any exposed reinforcing, as none was identified. • Bypass of the existing wet well • Upgrade to any mechanical, electrical, or structural components (however include anchoring structural components.)
Key Information
Details
- Compliance with Contract and SpecificationTenderers must comply fully with the contract and specification requirements as stated in the RfT documents. Non-compliance may result in disqualification.
- Insurance RequirementsTenderers must provide certificates of insurance including Public Liability, Professional Indemnity, and WorkCover Insurance.
- Occupational Health and Safety ManagementTenderers must demonstrate compliance with OH&S requirements and acknowledge current active status on North East Water OHS Contractor Register or submit an application.
- 100% detailed design report and specification of concrete remediation
- Product technical data sheets confirming design life of remediation products
- Project timeline including mobilisation, construction, curing and handover
Assessment of benefits including quality levels, performance standards, and environmental impacts; lowest cost not necessarily preferred.
Tenderer's compliance with contract terms.
Tenderer's compliance with the functional and technical specifications.
Technical capability including past performance, quality and fitness for purpose of proposed engineering solution and construction methodology.
Ability to meet the project completion date.
Compliance with OH&S requirements and management systems.
- Method
- Online portal
- Portal
- https://buyingfor.vic.gov.au/browse-tenders
- Contact
- Curtis Biggs, Coordinator Mechanical and Project Maintenance, Mobile: 0418718253, Email: procurement@newater.com.au
- •Tender must remain valid for minimum 120 days from closing date.
- •Alternative tenders allowed if fully compliant tender also submitted.
- •No remediation of exposed reinforcing required as none identified.
- •Bypass of existing wet well excluded.
- •No upgrades to mechanical, electrical, or structural components except anchoring structural components.
Supporting Documents
Sign in to download documents
Chat with Documents
AI PreviewSign in to chat with grant documents and get instant answers